IEC 60027 Letter symbols to be used in electrical technology

 IEC 60034 Rotating electrical machinery

IEC 60038 IEC Standard Voltages

IEC 60050 International electro technical vocabulary

IEC 60062 Marking codes for resistors and capacitors

IEC 60065 Audio, video and similar electronic apparatus - Safety requirements

IEC 60068 Environmental Testing

IEC 60086 Primary batteries

      •     IEC 60086-3 Watch batteries

IEC 60094 Magnetic tape sound recording and reproducing systems

·          IEC 60094-5 Electrical magnetic tape properties

·          IEC 60094-6 Reel-to-reel systems

·IEC 60094-7 Cassette for commercial tape records and domestic use

· IEC 60096 Radio-frequency cables

IEC 60098 Rumble measurement on Vinyl Disc Turntables

IEC 60134 Absolute maximum and design ratings of tube and semiconductor devices

IEC 60169 Radio-frequency connectors

·          IEC 60169-2 unmatched coaxial connector (Belling-Lee TV Aerial Plug)

·          IEC 60169-8 BNC connector, 50 ohm

·          IEC 60169-9 SMC connector, 50 ohm

·          IEC 60169-10 5MB connector, 50 ohm

·          IEC 60169-15 N connector, 50 ohm or 75 ohm

·          IEC 60169-16 SMA connector, 50 ohm

·          I EC 60169-16 TNC connector, 50 ohm

·IEC 60169-24 F connector, 75 ohm

· IEC 60179 Sound Level Meters

IEC 60228 Conductors of insulated cables IEC 60238 Edison screw lamp holders

IEC 60255 Electrical Relays

IEC 60268 Sound system equipment

·          I EC 60268-1 General

·          IEC 60268-2 Explanation of general terms and calculation methods

·          IEC 60268-3 Amplifiers

·          IEC 60268-4 Microphones

·          I EC 60268-5 Loudspeakers

·          IEC 60268-6 Auxiliary passive elements

·          I EC 60268-7 Headphones and earphones

·          IEC 60268-8 Automatic gain control devices

·          IEC 60268-9 Artificial reverberation, time delay and frequency shift equipment

·          IEC 60268-10 Peak programmed level meters

·          IEC 60268-11 Application of connectors for the interconnection of sound system components

 

  ·         IEC 60268-13 Listening tests on loudspeakers

IEC 60268-12 Application of connectors for broadcast and similar use

  ·  IEC 60268-13 Listening tests on loudspeakers

IEC 60268-14 Circular and elliptical loudspeakers; outer frame diameters and mounting

Dimensions

·          IEC 60268-16 Objective rating of speech intelligibility by speech transmission index

·          IEC 60268-17 Standard volume indicators

·          I EC 60268-18 Peak program level meters - Digital audio peak level meter

·          IEC 60297 19-inch rack

IEC 60309 Plugs, socket-outlets and couplers for industrial purposes

IEC 60317 Specifications for particular types of winding wires

IEC 60320 Appliance couplers for household and similar general purposes

IEC 60331 Tests for Electric Cables under Fire Conditions

IEC 60332-3 Flame Retardance Test

IEC 60335 Safety of electrical household appliances

 IEC 60364 Electrical installations of buildings

IEC 60386 Method of measurement of speed fluctuations in sound recording and reproducing equipment

IEC 60417 Graphical symbols for use on equipment

IEC 60446 Wiring colors

IEC 60529 Degrees of protection provided by enclosures (IP Code)

 IEC 60574 Audio-visual, video and television equipment and systems

IEC 60529 Degrees of protection provided by enclosures (IP Code)

IEC 60598-1 Luminaires: General Requirements

IEC 60601-1 Medical Electrical Equipment - Part 1: General Requirements for Safety.

·         IEC 60601-1-1 Medical electrical equipment - Part 1-1: General requirements for safety Collateral standard: Safety requirements for medical electrical system.

·         I EC 60601-1-2 Medical electrical equipment - Part 1-2 : General requirements for safety - Section 2: Collateral standard: Electromagnetic compatibility - Requirements and tests.

·         IEC 60601-1-4 Medical Electrical Equipment - Part 1-4: General Requirements for Safety Collateral Standard. Programmable Electrical Medical Systems.

·         IEC 60601-1-8 Medical Electrical Equipment - Part 1-8: General Requirements for Safety Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems. First edition in August 2003

·          IEC 60601-1-9 Medical electrical equipment - Part 1-9: General requirements for basic safety and essential performance - Collateral Standard: Requirements for environmentally conscious design. First Edition Jul 2007

IEC 60603 Connectors for frequencies below 3 MHz for use with printed boards

      •     IEC 60603-7 RJ45 connector (8-pin)

IEC 60617 Graphical symbols for diagrams

      •     IEC 60617-12 Binary logic elements

IEC 60651 Sound level meters

IEC 60694 High-voltage switchgear. Common specifications

 IEC 60721 Classification of environmental conditions

IEC 60747 Semiconductor devices

IEC 60748 Semiconductor devices - integrated circuits

IEC 60754-1/2 Test fir halogens & corrosive gases

IEC 60774 VHS/S-VHS video tape cassette system

IEC 60793 Optical fibers

I EC 60825 Laser safety

IEC 60870 Tele control equipment and systems

·          I EC 60870-1 General considerations

·          IEC 60870-2 Operating conditions

·          IEC 60870-3 Interfaces (electrical characteristics)

·          IEC 60870-4 Performance requirements

·          IEC 60870-5 Transmission protocols

IEC 60870-5-101 Companion standard for basic tele control tasks

I EC 60870-5-102 Companion standard for the transmission of integrated totals in electric power systems

IEC 60870-5-103 Companion standard for the informative interface of protection equipment

IEC 60870-5-104 Network access for IEC 60870-5-101 using standard transport profiles

IEC 60870-6 Telecontrol protocols compatible with ISO and ITU-T recommendations

IEC 60874 Connectors for optical fibers

IEC 60884 Plugs and socket-outlets for household and similar purposes

Defines general requirements of such plugs and sockets. The many particular forms used in different countries are listed in I ECITR 60083 (formerly IECEE CEE-7).

IEC 60906 IEC system of plugs and socket-outlets for household and similar purposes

IEC 60906-1: Plugs and socket-outlets 16 A 250 V AC

This is the system the IEC recommends as the worldwide standard for countries using 220-240 V AC. Switzerland uses already a very similar plug.

IEC 60906-2: Plugs and socket-outlets 15 A 125 V AC

This is the system used in the United States, Canada, and Japan.

IEC 60906-3: SELV plugs and socket-outlets, 16 A 6V, 12 V, 24 V, 48 V, AC and DC

IEC 60908 Compact disk digital audio system

IEC 60921 Ballasts for tubular fluorescent lamps - Performance requirements

IEC 60929 AC-supplied electronic ballasts for tubular fluorescent lamps - Performance requirements

IEC 60947 Standards for low-voltage switchgear and control gear

IEC 60950 Safety of information technology equipment

IEC 61000 Electromagnetic compatibility (EMC)

·         I EC 61000-2-1 : Guide to electromagnetic environment for low-frequency conducted disturbances and signaling in public power supply systems

·          IEC 61000-2-7: Environment - Low frequency magnetic fields in various environments

·          IEC 61000-2-9: Environment - Description of HEMP environment. Radiated disturbance. Basic EMC publication

·          IEC 61000-2-10: Environment - Description of HEMP environment. Conducted disturbance

·         IEC 61000-3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

·         IEC 61000-3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current s 16 A per phase and not subject to conditional connection

·         IEC 61000-3-4: Limits - Limitation of emission of harmonic currents in low-voltage power supply systems for equipment with rated current greater than 16 A

·         IEC 61000-3-7: Limits - Assessment of emission limits for fluctuating loads in MV and HV power systems

·         IEC 61000-3-8: Limits - Guide to signaling on low-voltage electrical installations. Emission levels, frequency bands and electromagnetic disturbance levels

·         IEC 61000-3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems. Equipment with rated voltage current s 75 A and subject to conditional connection

·          I EC 61000-4-1 : Testing and measurement techniques - Overview of IEC 61000-4 series

·          IEC 61000-4-2: Testing and measurement techniques - Electrostatic discharge immunity tests.

Basic EMC publication

·         IEC 61000-4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

·         IEC 61000-4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test. Basic EMC publication

·          IEC 61000-4-5: Testing and measurement techniques - Surge immunity test

·         IEC 61000-4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

·         IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test. Basic EMC publication

·         IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test. Basic EMC publication

·         IEC 61000-4-10: Testing and measurement techniques - Damped oscillatory magnetic field immunity test. Basic EMC publication

·         IEC 61000-4-12: Testing and measurement techniques - Oscillatory waves immunity test. Basic EMC publication

·         IEC 61000-4-13: Testing and measurement techniques - Harmonics and inter harmonics including mains signaling at A.C. power port, low frequency immunity tests

·          I EC 61000-4-14: Testing and measurement techniques - Voltage fluctuation immunity test

·         IEC 61000-4-15: Testing and measurement techniques - Flicker meter. Functional and design specifications. Basic EMC publication

·         I EC 61000-4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz

·         IEC 61000-4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test

·         IEC 61000-4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances

·         IEC 61000-4-24: Testing and measurement techniques - Test methods for protective devices for HEMP conducted disturbance. Basic EMC publication

·         IEC 61000-4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems

·          IEC 61000-4-27: Testing and measurement techniques - Unbalance, immunity test

·         IEC 61000-4-28: Testing and measurement techniques - Variation of power frequency, immunity test

·          IEC 61000-4-29: Testing and measurement techniques - Testing and measurement techniques.

Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests

·         IEC 61000-5-1: Installation and mitigation guidelines - General considerations. Basic EMC publication

·          IEC 61000-5-2: Installation and mitigation guidelines - Earthing and cabling

 

·          IEC 61000-5-5: Installation and mitigation guidelines - Specification of protective devices for HEMP conducted disturbance. Basic EMC publication

·         I EC 61000-6-1 :Generic standard -EMC - Susceptibility - Residential, Commercial and Light

industry

·         IEC 61000-6-2: Generic standard - EMC - Susceptibility - Industrial

·         IEC 61000-6-3: Generic standard - EMC - Emissions - Residential, Commercial and Light industry

·         IEC 61000-6-4: Generic standard - EMC - Emissions - Industry

·         IEC 61000-6-6: Generic standards - HEMP immunity for indoor

·         equipment

IEC 61034-1/2 Test for smoke emission

IEC 61043 Sound intensity meters with pairs of microphones IEC 61131 PLC programming.

IEC 61131-3 defining PLC programming languages. I EC 61149 Safety of mobile radios

IEC 61158 Digital data communications for measurement and control - Field bus for use in industrial control systems

IEC 61158-SER Digital data communications for measurement and control - Field bus for use in industrial control systems - ALL PARTS

IEC 61158-1 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 1: Overview and guidance for the IEC 61158 series

IEC 61158-2 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 2: Physical layer specification and service definition

IEC 61158-3 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 3: Data link service definition

IEC 61158-4 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 4: Data link protocol specification

IEC 61158-5 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 5: Application layer service definition

IEC 61158-6 Digital data communications for measurement and control - Field bus for use in industrial control systems - Part 6: Application layer protocol specification

IEC 61280 Field testing method for measuring single mode fiber optic cable

IEC 61286 Character set with electro technical symbols (ISO-IR 181 [2])

IEC 61355 Classification and designation of documents for plants, systems and equipment

IEC 61400 Wind turbines

·         61400-1: Design requirements

·         61400-2: Design requirements for small wind turbines

·         61400-3: Design requirements for offshore wind turbines

·         61400-11 : Acoustic noise measurement techniques

·         61400-12: Wind turbine power performance testing

·         61400-12-1: Power performance measurements of electricity producing wind turbines

·         61400-13: Measurement of mechanical loads

·         61400-14: Declaration of apparent sound power level and tonality values

·         61400-21: Measurement and assessment of power quality characteristics of grid connected wind turbines

·         61400-23: Full-scale structural testing of rotor blades

 

·         61400-24: Lightning protection

·         61400-25-1: Communications for monitoring and control of wind power plants - Overall description of principles and models

·         61400-25-2: Communications for monitoring and control of wind power plants - Information models

·         61400-25-3: Communications for monitoring and control of wind power plants - Information exchange models

·         61400-25-4: Communications for monitoring and control of wind power plants - Mapping to communication profile

·         61400-25-5: Communications for monitoring and control of wind power plants - Conformance testing

 

 

IEC 61499 Function blocks

·          I EC 61499-1 Architecture

·          IEC 61499-2 Software tool requirements

·          IEC 61499-3 Tutorial information

·          IEC 61499-4 Rules for compliance profiles

IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems

IEC 61511 Functional safety - safety instrumented systems for the process industry sector

IEC 61557 Equipment for measuring electrical safety in low-voltage distribution systems

IEC 61588 Precision clock synchronization protocol for networked measurement and control systems

IEC 61603 Infrared transmission of audio or video signals

 

IEC 61690 Electronic design interchange format, EDIF

·          I EC 61690-1 Version 3 0 0

·          IEC 61690-2 Version 400

 

IEC 61784 Digital data communications for measurement and control

·          IEC 61784-1 Digital data communications for measurement and control - Part 1: Profile sets for

continuous and discrete manufacturing relative to field bus use in industrial control systems

IEC 61800 Adjustable speed electrical power drive systems

IEC 61850 Communication Networks and Systems in Substations

 IEC 61966 Multimedia systems -- Color measurement

·          IEC 61966-2-1 sRGB default RGB color space

·          IEC 61966-2-4 xvYCC, the extended-gamut YCC color space

IEC 61968 Application integration at electric utilities - System interfaces for distribution management

IEC 61970 Application integration at electric utilities - Energy management system application program interface (EMS-API)

IEC 62056 DLM/COSEM communication protocol for reading utility meters

IEC 62196 Plugs and sockets for charging electric vehicles

IEC 62270 Hydroelectric power plant automation - Guide for computer-based control

IEC 62271 Standards for high-voltage switchgear and control gear

·          I EC 62271-100 High-voltage alternating current circuit breakers

·          I EC 62271-102 Alternating current disconnections and earthing switches

·          I EC 62271-107 AC Fuse Switches 1-52kV

·         IEC 62271-200 AC metal-enclosed switchgear and control gear for rated voltages above 1 kVand up to and including 52 kV

IEC 62271-203 Gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above

+ نوشته شده در  سه شنبه 20 مرداد1388ساعت 15:54  توسط احمد طالبی  | 

ارت فالت

کلید های ارت فالت و نشتی جریان  

کلید های ارت فالت و نشتی جریان   

 

یکی از عوامل اصلی در بروز خسارات مالی ، صدمات و تلفات جانی به ویژه در منازل مسکونی ، مراکز اداری ، تجاری و مجتمع های صنعتی عدم رعایت مسائل ایمنی در استفاده از انرژی برق میباشد .

        بمنظور حفاظت از جان افراد در مقابل خطر برق گرفتگی و جلوگیری از خطرات جریان نشتی از کلیدهای حفاظت از خطر برق گرفتگی ( محافظ جان ) استفاده می شود . این کلیدها که براساس حساسیت خود به دو نوع خانگی و صنعتی تقسیم می شوند ، علاوه بر حفاظت افراد در مقابل تماس مستقیم و یا غیر مستقیم برق ، با جلوگیری از نشتی جریان در حفاظت دستگاه ها و تجهیزات صنعتی نیز موثر می باشند . براین اساس در صورتی که حساسیت کلیدها تا 30 میلی آمپر باشد این کلید به عنوان حفاظت از جان و در صورتی که حساسیت آن بیشتر از 30 میلی آمپر باشد به عنوان حفاظت از تجهیزات صنعتی بکار می رود .

       اساس کار کلیدهای حفاظت از خطر برق گرفتگی ، مقایسه جریان ورودی با جریان خروجی کلید می باشد به طوری که اگر جریان نشتی در مداری که کلید در آن واقع شده است بیشتر از حساسیت کلید باشد کلید عمل کرده و جریان ورودی و در نتیجه مدار را قطع می نماید .

       از مزایای دیگر استفاده از کلیدهای حفاظت از خطر برق گرفتگی جلوگیری از بروز آتش سوزی در اثر وجود جریان نشتی می باشد . باتوجه به اینکه یم جریان 5/0 آمپری می توان باعث بروز آتش سوزی شود ، کلید حفاظت از خط برق گرفتگی با تشخیص جریان نشتی و قطع جریان ورودی ، مانع از بروز آتش سوزی می شود . همچنین از آنجا که در صورت وجود جریان نشتی در بدنه وسائل برقی و یا سیستم سیم کشی ساختمان ، این جریان به مرور زمان یاد می شود و احتمال سوختن وسایل برقی و سیستم سیم کشی ساختمان را به وجود می آورد لذا استفاده از کلیدهای حفاظت از خطر برق گرفتگی ، با توجه به کاهش میزان هدر رفتن انرژی الکتریکی و برق مصرفی . صرفه جوئی اقتصادی و حفظ ثروتهای ملی را نیز در بر خواهد داشت .

 

     الف- مشخصات کلیدهای حفاظت از خطر برق گرفتگی ( جریان نشتی ) :

1.       دمای کاری کلیدها جهت قطع جریان نشتی متناوب   از 25- تا 40- درجه سیلسیوس و با قدرت اتصال کوتاه 6 تا 25 کیلو آمپر می باشد .

2.       جهت حفاظت کـلـیـدهـا و مـدار مصرفی در مـقـابـل اتصال کوتاه و اضافه بار بایستی فیوز پشتیبان (Back-Up Fuse) با توجه به جریان نامی کلید و مشخصات ارائه شده در کاتالوگ نصب گردد .

3.       کلیدها با جریان نامی 125-16 آمپر تولید می شوند .

4.       کلیدها جهت استفاده مشترکین تکفاز ( خـانـگی ) بـه صورت دو پـل ( فـاز + نـول ) و مشترکین سه فـاز ( صنعتی ) به صورت چهار پل ، که می تواند همراه با نول و یا بدون نول ( در سیستم های سه سیمه ) بکار رود .

5.       میزان جریان قطع خودکار کلیدها ( حساسیت ) از 10 میلی آمپر تا 5/1 آمپر ، و مدت زمان قطع حداکثر 200 میلی ثانیه است .

 

     ب- دستور العمل نصب :

      باتوجه به مقررات و استانداردهای بین المللی ، رعایت موارد ذیل در نصب کلیدهای محافظ جان ضروری می باشد :

1-      قبل از نصب بایستی با آمپرمتر مخصوص میزان نشتی جریان در مداری که قرار است . کلید فوق نصب گردد اندازه گیری شود و در صورتیکه میزان جریان نشتی بیشتر از 2% حساسیت نامی کلید باشد پس از نشت یابی و رفع نقص ، اقدام به نصب کلید گردد. این نشتی می تواند بین فاز و زمین ، نول و زمین ، فاز یا نول با فازها و نول ها مدارهای مجاور باشد که در تمام حالت های فوق کلید اقدام به قطع مدار می نماید .

2-      در مورد کلیدهای دو پل سیم نول به ترمینال مشخص شده با علامت N و سیم فاز به ترمینال مشخص شده با علامت L متصل می شود .

3-      در سیستم تکفاز ، دو سیم نول و فاز و در سیستم سه فاز ، چهار سیم ( سه فاز و نول ) بایستی به ورودی و خروجی کلید متصل گردد.

4-      باتوجه به موقعیت نصب ، سیم های ورودی و خروجی می توانند از بالا و یا پائین به کلید متصل شوند که این امر در کارکرد کلید اثری نخواهد داشت .

5-      درجه حفاظت کلیدها برای جلوگیری از ورود اجسام خارجی برابر با IP 40 می باشد.

6-      کلید عملیات نصب و رفع نقص بایستی توسط فرد متخصص انجام شود .

7-      ترمینال های ورودی و خروجی کلیدها باتوجه به آمپر کلید برای بالاترین قطر کابل یا سیم در نظر گرفته شده و از این نظر مشکلی وجود نخواهد داشت .

8-      همراه با کلید امکان استفاده از کنتاکت کمکی نیز وجود دارد .

 

     ب- دستور العمل دوره بهره برداری :

      قطع جریان برق توسط کلید محافظ جان نشان دهنده آن است که حداقل یکی از وسایل برقی موجود در مدار و یا اینکه سیم کشی ساختمان دارای جریان نشتی می باشد که در این صورت باید ابتدا دو شاخه کلیه وسائل برقی را از پریزها بیرون آورده و پس از وصل مجدد کلید حفاظت از خطر برق گرفتگی مطابق با موارد زیر عمل نمود:

 

1-     چنانچه کلید دوباره جریان برق را قطع نمود :

     این امر بدین معنی است که در سیستم سیم کشی داخل ساختمان و یا سیم های خروجی از مدار کلید حفاظت از خطر برق گرفتگی جریان نشتی بوجود آمده است و تا زمانی که این نشتی وجود داشته باشد کلید قابل وصل نخواهد بود و هربار پس از وصل کلید ، بلافاصله فرمان قطع می دهد که در این صورت بایستی توسط فرد متخصص نسبت به رفع نقص اقدام گردد .

 

2-     در صورتی که بعد از خارج نمودن کلیه وسایل برقی از مدار ، کلید حفاظت از خطر برق گرفتگی ، جریان برق را قطع نکند :

 

     این امر بدین معنی است که در سیستم سیم کشی ساختمان مشکلی ندارد و یکی از وسائل برق داری جریان نشتی به بدنه می باشد که در این صورت وسائل برقی را تک تک به برق وصل نموده تا کلید قطع نماید ، قطع کلید نشانه آن است که آن وسیله برقی دارای جریان نشتی به بدنه می باشد که بایستی نسبت به رفع نقص آن اقدام گردد .

     در روی هر کلید حفاظت از خطر برق گرفتگی یک شاسی کلید قطع و وصل جهت قطع و وصل جریان عبوری از کلید ، و یک شاسی فشاری زرد رنگ بمنظور تست عملکرد کلید بکار رفته است . با فشار شاسی تست یک جریان نشتی مجازی به وجود می آید و باعث قطع کلید می گردد لذا حداقل هرماه یک بار می بایست از این دکمه استفاده نمود و در صورت کاربرد شاسی تست و عدم قطع مدار ، بایستی حتما" به مسئول نصب اطلاع داده شود تا نسبت به تعویض کلید اقدام نماید .

 

     با استفاده از کلیدهای حفاظت از خطر برق گرفتگی یک عمر آسایش و امنیت و صرفه جوئی اقتصادی خواهید داشت .


 
+ نوشته شده در  سه شنبه 20 مرداد1388ساعت 15:51  توسط احمد طالبی  | 

ارائه الکترود و روش اجرای جدیدی برای سیستم اتصال زمین در شبکه توزیع

در گذشته یکی از رایج ترین روشها جهت نصب الکترود و کاهش مقاومت زمین و زمین های دارای مقاومت بالا، استفاده از خاک رس، نمک و زغال بود که سالها در کشور به صورت سنتی اجرا می شد. از جمله مشکلات عمده مربوط به استفاده از این الکترولیت تجزیه تریجی زغال و قطع اتصالات فلزی الکترود بر اثر خاصیت خوردگی نمک می باشد که باعث می گردد مقاومت بسیاری از اینگونه اتصال زمین پس از چند سال به شدت افزایش یابد.

این مطلب توسط دوست عزیزمان مهدی پراینده شهرستانی گردیده است. امید است مورد توجه قرار گیرد.

  دانلود متن کامل با فرمت pdf (احمد)

+ نوشته شده در  دوشنبه 19 مرداد1388ساعت 15:36  توسط احمد طالبی  | 

الکترونیک

+ نوشته شده در  پنجشنبه 8 مرداد1388ساعت 13:37  توسط احمد طالبی  |